B1445 01

Trigger Circuit CIM-SCL, Open/Short to B+

SDI CGM SVG Version 1.58 Date:2018-12-06 7 0 8 5 1 6 3 4 2 J7 0 H3 3 -1 19 20 25 24 G 4 0 10 11 + 3 0 1 2 2 1 CPU CPU 46 3 2 0 ST O N O FF LO C K 7 0 3 F70806 060719

Fault symptom

Engine does not start.

Steering column lock not working.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Diagnostics run when key is inserted and removed.

Fault criteria:

Trigger lead of steering column lock unit shorted to B+/open-circuit.

System reaction to a fault:

Steering column lock deactivated.
The control module does not allow starter motor cranking.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
SCL Voltage, Unlocked and Secured
(See also description of readings/activations in diagnostic tool)